Once your DeviceTypes are laid out and your Devices have WDM nodes and line ports, the next setup task is cabling. The plugin auto-discovers wavelength paths from the cable plant, but only if cables are wired in patterns it can follow. This page lists the patterns netbox-wdm understands and the small rules that keep tracing honest.

What the trace follows

trace_wavelength_path() walks the cable plant by alternating between two operations:

  1. Internal pass-through. From a FrontPort, follow the device's PortTemplateMapping-derived dcim.PortMapping to the matching RearPort at the channel's grid_position.
  2. External cable. From a RearPort or FrontPort, follow the dcim.Cable to the next device's port.

The tracer alternates these two operations until it finds a non-WDM endpoint or hits a dead end. Anything you cable that fits this alternating pattern (front -> internal -> rear -> cable -> rear -> internal -> front on the next device, and so on) becomes part of a wavelength path.

Single-fibre cabling

Single-fibre topologies use one dcim.Cable per fibre run. Each cable has a single termination on each end:

[MUX-A.COM]  --cable-->  [PP-A.RP-01]
[PP-A.FP-01] --cable-->  [PP-B.FP-01]
[PP-B.RP-01] --cable-->  [MUX-B.COM]

Three cables connect two single-fibre MUXes through a pair of patch panels. The plugin treats each cable as one hop in the wavelength path. Bidirectional traffic shares the same physical fibre, so a single wavelength produces a single path.

The helper cable_through_pp_pair in netbox_wdm.testing.cabling is the canonical reference for this pattern.

Duplex (multi-terminated) cabling

Duplex topologies use multi-terminated cables. A single dcim.Cable carries both fibres of the pair as a list of terminations:

[MUX-A.COM-TX, MUX-A.COM-RX]  --cable-->  [PP-A.FP-01, PP-A.FP-02]
[PP-A.RP-01, PP-A.RP-02]      --cable-->  [PP-B.RP-01, PP-B.RP-02]
[PP-B.FP-01, PP-B.FP-02]      --cable-->  [MUX-B.COM-RX, MUX-B.COM-TX]

A duplex link between two MUXes via a patch panel pair therefore needs three cables, not six. Each cable's a_terminations and b_terminations are lists of two ports each.

The trace code follows the right fibre by combining two pieces of information per hop:

  • The cable_end (A or B) of the port on the cable.
  • The position index of the port within its end's termination list.

Position 0 in the A-end maps to position 0 in the B-end, and so on. This is how the tracer separates the TX leg from the RX leg through a single multi-terminated cable.

When you wire duplex cables in the NetBox UI:

  • Use the cable form's multi-termination support (a comma-separated list of port names on each side).
  • The order of terminations on the A side defines the fibre indexing on that cable. The corresponding port at the same index on the B side is what the trace will follow.

A duplex MUX always has its TX and RX listed in TX, RX order on the MUX side. On the patch panel side, list FrontPorts in the same TX, RX order on the device-A side, and in RX, TX order on the device-B side, since the TX leg of A connects to the RX leg of B and vice versa.

The helper cable_duplex_through_pp_pair in netbox_wdm.testing.cabling is the canonical reference. The order of arguments (device_a_tx_rp, device_a_rx_rp, ..., device_b_rx_rp, device_b_tx_rp) encodes the TX/RX flip on the far side.

MUX-to-ROADM cabling

A duplex MUX terminating on one side of a ROADM follows the same duplex cabling pattern, but the ROADM end uses one of its line ports instead of a COM rear port:

[MUX.COM-TX, MUX.COM-RX]
    -- duplex via PP pair -->
[ROADM.LINE-EAST-RX, ROADM.LINE-EAST-TX]

Note the swap at the ROADM end: MUX.COM-TX talks to ROADM.LINE-EAST-RX (TX-to-RX), and MUX.COM-RX talks to ROADM.LINE-EAST-TX. This is the same convention as wiring two MUXes together, only the names are different.

For MUX-to-ROADM-to-MUX pass-through, build a duplex link to each side of the ROADM:

[MUX-A]  -- duplex via PP-EA/PP-EB -->  [ROADM.LINE-EAST]
                                              ROADM
[MUX-B]  -- duplex via PP-WA/PP-WB -->  [ROADM.LINE-WEST]

The trace finds pass-through wavelengths automatically: when it lands on the ROADM's RX line port, it tries every TX line port on the same node to see which one lets the trace continue, and follows the one that reaches an unvisited node. This is what makes a single wavelength path span MUX-A -> PPs -> ROADM -> PPs -> MUX-B.

Direct device-to-device cabling

Patch panels are optional. You can cable a MUX directly to another MUX or to a ROADM with the same termination conventions; the trace just records one fewer hop. Use this for point-to-point lab setups or for short metro spans where the patch plant is collapsed.

Cable status and path activation

A wavelength path's is_active flag turns on when:

  • Every cable in the path has status = connected, and
  • The path has at least two hops.

Cables with status planned, decommissioning, or any non-connected value will produce a wavelength path object (so you can preview the intent), but is_active stays false until every cable along it is connected. Use this to plan installs in advance and flip cables to connected as turn-up progresses.

Validity checks

The trace flags a few cable-plant errors as is_valid = false on the resulting wavelength path:

  • TX-to-TX miscable. When the tracer detects that a TX rear port on one side connects (eventually) to a TX rear port on the other side through the cable plant, it marks the path invalid. This catches the most common patching mistake -- forgetting to flip TX/RX at the far end.
  • Incomplete path. When neither end of the path has a client port assigned, is_complete is false. This is normal during install, but on a turned-up service it usually means the wavelength editor has not been used yet on a ROADM endpoint.

Both conditions are visible in the Wavelength Paths list and on the trace visualisation, so you can spot miscables without instrumenting the optical hardware.

Updating cables

When a cable is created, modified, or deleted, post_save and post_delete signal handlers schedule rebuild_wavelength_paths_for_node on transaction commit for every WDM node touched by the change. Path discovery is fully automatic; there is no UI button to trigger a rebuild and no batch job that needs to run on a schedule.

If you change the terminations on a duplex multi-terminated cable (reordering them, for example), the rebuild fires and the new fibre mapping is reflected in any path that traverses that cable. The trace visualisation reloads on the next page hit.

Reference helpers

The helpers in netbox_wdm.testing.cabling are reference implementations of these patterns. If you provision a cable plant from a script:

from netbox_wdm.testing import (
    cable_through_pp_pair,        # 3 simplex cables MUX-PP-PP-MUX
    cable_duplex_through_pp_pair, # 3 duplex (multi-term) cables MUX-PP-PP-MUX
)

They are not part of the runtime plugin code path; they are exposed for test fixtures and one-off scripts that need to build realistic cable plants quickly.